glass suction electrodes Search Results


90
Harvard Bioscience borosilicate glass suction electrodes
Borosilicate Glass Suction Electrodes, supplied by Harvard Bioscience, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/glass+suction+electrodes/borosilicate+glass+suction+electrodes/pmc04319907-101-13-25
Average 90 stars, based on 1 article reviews
borosilicate glass suction electrodes - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Digitimer Ltd glass suction electrodes
Glass Suction Electrodes, supplied by Digitimer Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/glass+suction+electrodes/glass+suction+electrodes/pmc05566179-59-4-13
Average 90 stars, based on 1 article reviews
glass suction electrodes - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Hilgenberg gmbh suction electrodes made from borosilicate glass
Suction Electrodes Made From Borosilicate Glass, supplied by Hilgenberg gmbh, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/glass+suction+electrodes/suction+electrodes+borosilicate+glass/pm31296565-233-18-20
Average 90 stars, based on 1 article reviews
suction electrodes made from borosilicate glass - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
SuperTech Inc suction electrode borosilicate glass capillary
Suction Electrode Borosilicate Glass Capillary, supplied by SuperTech Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/glass+suction+electrodes/suction+electrode+borosilicate+glass+capillary/pmc05264160-162-14-27
Average 90 stars, based on 1 article reviews
suction electrode borosilicate glass capillary - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Instrumente GmbH glass suction electrodes
Physiological approaches. The modulatory effects of myosuppressin on cardiac muscle were assessed in two ways: ( A ) measuring changes in glutamate-evoked muscle contractions, and ( B ) measuring changes in the postsynaptic responses (excitatory junction potentials; EJPs) that were evoked by stimulating the terminal segment of the posterior lateral motor nerve that innervates the transverse muscle (TM). ( A ) Photograph of the dissected lobster heart that has been cut along the ventral, rostral–caudal axis to reveal the cardiac ganglion (CG) and associated cardiac muscles. The preparation was stained using methylene blue to visualize nerve and muscle tissue. A force transducer (FT) was used to measure contractions in one of the TM. Contractions were evoked in the absence of the CG (dissected out; indicated by the “X” over the CG) via focal application of glutamate (Glut, 5.5 × 10 −4 M). A representative force transducer trace is shown below the photograph with blue arrows indicating three instances of focally applied glutamate. ( B ) The same photograph used in (A) to show a schematic of how postsynaptic excitatory junction potentials (EJPs) were recorded. Similar to (A) , the CG was dissected away from the heart; however, in this approach, a segment of terminal nerve (no neurons present) was left intact so that a suction <t>electrode</t> (Stim.) could be used to stimulate the motor nerve. In this way, we were able to record single EJPs from the TM fibers using a sharp electrode (schematic on the right). EJPs were then amplified and recorded; an example recording is shown below the photograph with teal arrows indicating when each nerve stimulus was delivered (voltage transients are visible on the voltage trace).
Glass Suction Electrodes, supplied by Instrumente GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/glass+suction+electrodes/glass+suction+electrodes/pmc11816307-78-0-8
Average 90 stars, based on 1 article reviews
glass suction electrodes - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Harvard Bioscience krebs-filled glass capillary suction electrodes (agcl, 250 µm)
Physiological approaches. The modulatory effects of myosuppressin on cardiac muscle were assessed in two ways: ( A ) measuring changes in glutamate-evoked muscle contractions, and ( B ) measuring changes in the postsynaptic responses (excitatory junction potentials; EJPs) that were evoked by stimulating the terminal segment of the posterior lateral motor nerve that innervates the transverse muscle (TM). ( A ) Photograph of the dissected lobster heart that has been cut along the ventral, rostral–caudal axis to reveal the cardiac ganglion (CG) and associated cardiac muscles. The preparation was stained using methylene blue to visualize nerve and muscle tissue. A force transducer (FT) was used to measure contractions in one of the TM. Contractions were evoked in the absence of the CG (dissected out; indicated by the “X” over the CG) via focal application of glutamate (Glut, 5.5 × 10 −4 M). A representative force transducer trace is shown below the photograph with blue arrows indicating three instances of focally applied glutamate. ( B ) The same photograph used in (A) to show a schematic of how postsynaptic excitatory junction potentials (EJPs) were recorded. Similar to (A) , the CG was dissected away from the heart; however, in this approach, a segment of terminal nerve (no neurons present) was left intact so that a suction <t>electrode</t> (Stim.) could be used to stimulate the motor nerve. In this way, we were able to record single EJPs from the TM fibers using a sharp electrode (schematic on the right). EJPs were then amplified and recorded; an example recording is shown below the photograph with teal arrows indicating when each nerve stimulus was delivered (voltage transients are visible on the voltage trace).
Krebs Filled Glass Capillary Suction Electrodes (Agcl, 250 µm), supplied by Harvard Bioscience, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/glass+suction+electrodes/krebs+filled+glass+capillary+suction+electrodes++agcl++250+%C2%B5m+/10__1113_slash_jp278284-130-2-18
Average 90 stars, based on 1 article reviews
krebs-filled glass capillary suction electrodes (agcl, 250 µm) - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Hilgenberg gmbh monopolar suction electrodes realized by pulling tight-fitting glass pipettes
Physiological approaches. The modulatory effects of myosuppressin on cardiac muscle were assessed in two ways: ( A ) measuring changes in glutamate-evoked muscle contractions, and ( B ) measuring changes in the postsynaptic responses (excitatory junction potentials; EJPs) that were evoked by stimulating the terminal segment of the posterior lateral motor nerve that innervates the transverse muscle (TM). ( A ) Photograph of the dissected lobster heart that has been cut along the ventral, rostral–caudal axis to reveal the cardiac ganglion (CG) and associated cardiac muscles. The preparation was stained using methylene blue to visualize nerve and muscle tissue. A force transducer (FT) was used to measure contractions in one of the TM. Contractions were evoked in the absence of the CG (dissected out; indicated by the “X” over the CG) via focal application of glutamate (Glut, 5.5 × 10 −4 M). A representative force transducer trace is shown below the photograph with blue arrows indicating three instances of focally applied glutamate. ( B ) The same photograph used in (A) to show a schematic of how postsynaptic excitatory junction potentials (EJPs) were recorded. Similar to (A) , the CG was dissected away from the heart; however, in this approach, a segment of terminal nerve (no neurons present) was left intact so that a suction <t>electrode</t> (Stim.) could be used to stimulate the motor nerve. In this way, we were able to record single EJPs from the TM fibers using a sharp electrode (schematic on the right). EJPs were then amplified and recorded; an example recording is shown below the photograph with teal arrows indicating when each nerve stimulus was delivered (voltage transients are visible on the voltage trace).
Monopolar Suction Electrodes Realized By Pulling Tight Fitting Glass Pipettes, supplied by Hilgenberg gmbh, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/glass+suction+electrodes/monopolar+suction+electrodes+realized+by+pulling+tight+fitting+glass+pipettes/bio_rxiv__2024__07__15__603535-64-17-27
Average 90 stars, based on 1 article reviews
monopolar suction electrodes realized by pulling tight-fitting glass pipettes - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Nilaco corp small glass suction electrode fitted with a silver wire
Physiological approaches. The modulatory effects of myosuppressin on cardiac muscle were assessed in two ways: ( A ) measuring changes in glutamate-evoked muscle contractions, and ( B ) measuring changes in the postsynaptic responses (excitatory junction potentials; EJPs) that were evoked by stimulating the terminal segment of the posterior lateral motor nerve that innervates the transverse muscle (TM). ( A ) Photograph of the dissected lobster heart that has been cut along the ventral, rostral–caudal axis to reveal the cardiac ganglion (CG) and associated cardiac muscles. The preparation was stained using methylene blue to visualize nerve and muscle tissue. A force transducer (FT) was used to measure contractions in one of the TM. Contractions were evoked in the absence of the CG (dissected out; indicated by the “X” over the CG) via focal application of glutamate (Glut, 5.5 × 10 −4 M). A representative force transducer trace is shown below the photograph with blue arrows indicating three instances of focally applied glutamate. ( B ) The same photograph used in (A) to show a schematic of how postsynaptic excitatory junction potentials (EJPs) were recorded. Similar to (A) , the CG was dissected away from the heart; however, in this approach, a segment of terminal nerve (no neurons present) was left intact so that a suction <t>electrode</t> (Stim.) could be used to stimulate the motor nerve. In this way, we were able to record single EJPs from the TM fibers using a sharp electrode (schematic on the right). EJPs were then amplified and recorded; an example recording is shown below the photograph with teal arrows indicating when each nerve stimulus was delivered (voltage transients are visible on the voltage trace).
Small Glass Suction Electrode Fitted With A Silver Wire, supplied by Nilaco corp, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/glass+suction+electrodes/small+glass+suction+electrode+fitted+with+a+silver+wire/pmc11723772-34-26-28
Average 90 stars, based on 1 article reviews
small glass suction electrode fitted with a silver wire - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Corning Life Sciences suction electrode pyrex glass tube (2 od, wall) drawn to a small tip (90-300 pm id)
Physiological approaches. The modulatory effects of myosuppressin on cardiac muscle were assessed in two ways: ( A ) measuring changes in glutamate-evoked muscle contractions, and ( B ) measuring changes in the postsynaptic responses (excitatory junction potentials; EJPs) that were evoked by stimulating the terminal segment of the posterior lateral motor nerve that innervates the transverse muscle (TM). ( A ) Photograph of the dissected lobster heart that has been cut along the ventral, rostral–caudal axis to reveal the cardiac ganglion (CG) and associated cardiac muscles. The preparation was stained using methylene blue to visualize nerve and muscle tissue. A force transducer (FT) was used to measure contractions in one of the TM. Contractions were evoked in the absence of the CG (dissected out; indicated by the “X” over the CG) via focal application of glutamate (Glut, 5.5 × 10 −4 M). A representative force transducer trace is shown below the photograph with blue arrows indicating three instances of focally applied glutamate. ( B ) The same photograph used in (A) to show a schematic of how postsynaptic excitatory junction potentials (EJPs) were recorded. Similar to (A) , the CG was dissected away from the heart; however, in this approach, a segment of terminal nerve (no neurons present) was left intact so that a suction <t>electrode</t> (Stim.) could be used to stimulate the motor nerve. In this way, we were able to record single EJPs from the TM fibers using a sharp electrode (schematic on the right). EJPs were then amplified and recorded; an example recording is shown below the photograph with teal arrows indicating when each nerve stimulus was delivered (voltage transients are visible on the voltage trace).
Suction Electrode Pyrex Glass Tube (2 Od, Wall) Drawn To A Small Tip (90 300 Pm Id), supplied by Corning Life Sciences, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/glass+suction+electrodes/suction+electrode+pyrex+glass+tube++2+od++wall++drawn+to+a+small+tip++90+300+pm+id+/10__1152_slash_ajpendo__1981__240__3__e290-54-32-19
Average 90 stars, based on 1 article reviews
suction electrode pyrex glass tube (2 od, wall) drawn to a small tip (90-300 pm id) - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

Image Search Results


Physiological approaches. The modulatory effects of myosuppressin on cardiac muscle were assessed in two ways: ( A ) measuring changes in glutamate-evoked muscle contractions, and ( B ) measuring changes in the postsynaptic responses (excitatory junction potentials; EJPs) that were evoked by stimulating the terminal segment of the posterior lateral motor nerve that innervates the transverse muscle (TM). ( A ) Photograph of the dissected lobster heart that has been cut along the ventral, rostral–caudal axis to reveal the cardiac ganglion (CG) and associated cardiac muscles. The preparation was stained using methylene blue to visualize nerve and muscle tissue. A force transducer (FT) was used to measure contractions in one of the TM. Contractions were evoked in the absence of the CG (dissected out; indicated by the “X” over the CG) via focal application of glutamate (Glut, 5.5 × 10 −4 M). A representative force transducer trace is shown below the photograph with blue arrows indicating three instances of focally applied glutamate. ( B ) The same photograph used in (A) to show a schematic of how postsynaptic excitatory junction potentials (EJPs) were recorded. Similar to (A) , the CG was dissected away from the heart; however, in this approach, a segment of terminal nerve (no neurons present) was left intact so that a suction electrode (Stim.) could be used to stimulate the motor nerve. In this way, we were able to record single EJPs from the TM fibers using a sharp electrode (schematic on the right). EJPs were then amplified and recorded; an example recording is shown below the photograph with teal arrows indicating when each nerve stimulus was delivered (voltage transients are visible on the voltage trace).

Journal: Integrative Organismal Biology

Article Title: Peptidergic Modulation of the Lobster Cardiac System Has Opposing Action on Neurons and Muscles

doi: 10.1093/iob/obaf002

Figure Lengend Snippet: Physiological approaches. The modulatory effects of myosuppressin on cardiac muscle were assessed in two ways: ( A ) measuring changes in glutamate-evoked muscle contractions, and ( B ) measuring changes in the postsynaptic responses (excitatory junction potentials; EJPs) that were evoked by stimulating the terminal segment of the posterior lateral motor nerve that innervates the transverse muscle (TM). ( A ) Photograph of the dissected lobster heart that has been cut along the ventral, rostral–caudal axis to reveal the cardiac ganglion (CG) and associated cardiac muscles. The preparation was stained using methylene blue to visualize nerve and muscle tissue. A force transducer (FT) was used to measure contractions in one of the TM. Contractions were evoked in the absence of the CG (dissected out; indicated by the “X” over the CG) via focal application of glutamate (Glut, 5.5 × 10 −4 M). A representative force transducer trace is shown below the photograph with blue arrows indicating three instances of focally applied glutamate. ( B ) The same photograph used in (A) to show a schematic of how postsynaptic excitatory junction potentials (EJPs) were recorded. Similar to (A) , the CG was dissected away from the heart; however, in this approach, a segment of terminal nerve (no neurons present) was left intact so that a suction electrode (Stim.) could be used to stimulate the motor nerve. In this way, we were able to record single EJPs from the TM fibers using a sharp electrode (schematic on the right). EJPs were then amplified and recorded; an example recording is shown below the photograph with teal arrows indicating when each nerve stimulus was delivered (voltage transients are visible on the voltage trace).

Article Snippet: Glass suction electrodes pulled on a DMZ-Universal Puller (Zeitz-Instrumente Vertriebs GmbH, Planegg, Germany) were hand cut and fire polished using a microforge (MF-830 Narishige, Tokyo, Japan) to have a 100-μm opening at the tip.

Techniques: Muscles, Staining, Amplification